BEP Catalog 2024

BATTERY MANAGEMENT 21

bepmarine.com

DVSR: Dual Battery Charging Made Easy The Digital Voltage Sensing Relay (DVSR) provides a highly efficient but inexpensive solution for automatic charging of a second battery bank. It ensures correct charging while removing the risk of flat start batteries. When the voltage on the first bank rises sufficiently, the DVSR engages allowing the second battery bank to charge. When charging stops and voltage falls, the DVSR automatically isolates the battery banks, ensuring that engine start batteries are kept fully charged. Digital circuitry provides superior reliability and extremely low power consumption.

• Safely charge two or more independent battery banks from one charge source (alternator, battery charger…) • Charges engine starting batteries before combining auxiliary bank for charging • Protects start batteries from becoming flattened by domestic loads • Isolates electronics from harmful electrical surges from starter motors • Simple to install 3-wire connection, leaves alternator wiring intact • No volt drop vs. diode isolators • Ignition protected • Surface or panel mountable

Digital Technology Provides: • Multi voltage, auto selects between 12V and 24V DC operation • Digital circuits provide very low power consumption (<2mA in standby, up to 8x more efficient than analog models) and enhanced performance • Remote sensing circuitry allows optional connection from ignition switch, provides same functionality as single sense VSR and zero power consumption when engine is off • Zero stand by current draw when remote sensing circuit utilized with storage mode switch fitted (switch in open position) • Remote status LED output option

Rating Continuous

Rating Intermittent Engages

Part # OEM # LxWxH in

LxWxH mm Voltage

Disengages Cable to meet rating

710-140A 710-140A-B 2.75" x 2.75" x 2" 69 x 69 x 50 mm 12/24V 125A

140A

13.4/26.8V DC 12.8/25.6V DC 8AWG (8mm 2 )

START DVSR Operation (Shown for 12V System) DVSR Operation (shown for 12V system)

Charging begins but batteries remain isolated

Battery voltage rises to 13.4V on charging battery

The two battery banks are isolated

The charge source is removed, battery voltages begin to fall House Batt Positive + (Tinned stud) Orange sticker (Remote LED connection point) Start Batt Positive + (Tinned stud) Black wire - (Negative) Red wire (Ignition control/Storage mode)

Automatically engages to join the two battery banks for charging

Battery voltage falls below 12.8V, and the DVSR disengages

CSP6

BEP House Battery Isolator

POS BUS

NEG BUS

NAVIGATION LIGHTS

+

-

ANCHOR LIGHTS

+

-

CABIN LIGHTS

COCKPIT LIGHT

- + Optional LED

Pro Installer Fuseholder

Optional Orange

BILGE PUMP

House Battery

SPARE

Switch Panel

Optional cut here and join other end for ignition or storage mode control

BEP Emergency

Start Battery POSITIVE +

Wiring diagrams indicative of installation only, for full instructions see the BEP website: bepmarine.com

Parallel Isolator

Black Wire

House Battery POSITIVE +

DVSR

Red Loop

Optional Pro Installer Fusehlder

Optional Switch for Ignition or Storage Mode Control

+

Fuse

-

Engine

Start Battery

BEP Start Battery Isolator

Powered by