54 TOOLS & TESTERS
ancorproducts.com
8 Function Digital Multimeter • Auto ranging capability allows the meter to automatically determine the resolution based on the application • Clear LCD display • Lightweight, ergonomic design • Comfortable protective cover, with test lead hanging groove • Loud buzzer sound • Batteries: two AAA Batteries (not included) • Continuity ✓ , Diode Test ✓
703072
Specifications DC Voltage (V)
Range
Accuracy
200.0mV, 2000mV/2.000V, 20.00V, 200.0V, 250V 200.0mV, 2000mV/2.000V, 20.00V, 200.0V, 250V
200.0mV, 20.00V, 200.0V, 250V (0.7% + 3) 2000mV/2.000V (0.5% + 2)
AC Voltage (V)
200.0mV, 20.00V (1.0% + 2) 2000mV/2.000V (0.7% + 3) 200.0V, 250V (1.2% + 3)
DC Current (A)
200.0µA, 2000µA, 20.00mA, 200.0mA, 2.000A, 10.00A
200.0µA, 2000µA, 20.00mA, 200.0mA (1.0% + 2) 2.000A, 10.00A (1.2% + 5) 200.0µA, 2000µA, 20.00mA, 200.0mA (1.2% + 3) 2.000A, 10.00A (1.5% + 5) 200 (1.0% + 2) 2000/2.000k, 20.00k, 200.0k (0.8% + 2)
AC Current (A)
200.0µA, 2000µA, 20.00mA, 200.0mA, 2.000A, 10.00A
R
Resistance (Ω)
200.0 2000/2.000k, 20.00k, 200.0k, 20.00M, 200.0M
CM
C
US
250V
20.00M (1.2% + 3) 200.0M (5.0% + 10)
CONFORMS TO UL STD. 61010-1 & 61010-031 CERTIFIED TO CAN/CSA STD C22.2 Nos. 61010-1 & 61010-031
Capacitance (F)
2.000nF, 20.00nF, 200.0nF, 2.000µF, 20.00µF, 200.0µF, 2.000mF
2.000nF (REL Mode: 5.0% + 5) 20.00nF, 200.0nF, 2.000µF, 20.00µF, 200.0µF (4.0% + 8), 2.000mF (10%)
Overload Protection 250V rms CAT Rating CAT II 250V
True RMS 12 Function Digital Multimeter • Auto ranging capability allows the meter to automatically determine the resolution based on the application • Clear LCD display • Comfortable protective cover, with test lead hanging groove • High voltage warning • Auto power off functionality to save battery life • Batteries: two AAA Batteries (not included) • Continuity ✓ , Diode Test ✓ , NCV ✓
703073
Specifications DC Voltage (V)
Range
Accuracy
600.0mV, 6000mV/6.000V, 60.00V, 600.0V 600.0mV, 6000mV/6.000V, 60.00V, 600.0V
600.0mV, 60.00V, 600.0V (0.7% + 3) 6000mV/6.000V (0.5% + 2)
AC Voltage (V)
600.0mV, 60.00V (1.0% + 2) 6000mV/6.000V (0.7% + 3) 600.0V (1.2% + 3)
DC Current (A)
600.0µA, 6000µA, 60.00mA, 600.0mA, 6.000A, 10.00A
600.0µA, 6000µA, 60.00mA, 600.0mA (1.0% + 3) 6.000A, 10.00A (1.2% + 5) 600µA, 6000µA, 60.00mA, 600.0mA (1.2% + 3) 6.000A, 10.00A (1.5% + 5) 600 (1.0% + 2) 6000/6.000k, 60.00k, 600.0k (0.8% + 2) 60.00M (2.0% + 5) 9.999nF (REL Mode: 4.0% +10) 99.99nF, 999.9nF, 9.999µF, 99.99µF, 999.9µF (4.0% + 5), 9.999mF (10%)
AC Current (A)
600.0µA, 6000µA, 60.00mA, 600.0mA, 6.000A, 10.00A 600.0, 6000/6.000k, 60.00k, 600.0k, 60.00M 9.999nF, 99.99nF, 999.9nF, 9.999µF, 99.99µF, 999.9µF, 9.999mF
Resistance (Ω)
Capacitance (F)
R
CM
C
US
600V
CONFORMS TO UL STD. 61010-1 & 61010-031 CERTIFIED TO CAN/CSA STD C22.2 Nos. 61010-1 & 61010-031
Frequency (Hz) Temperature (°F)
10.00Hz–1.000MHz
10.00Hz–1.000MHz (0.1% + 5) -40 to 104°F (5%) 104°F to 932°F (1.5% + 5) 932°F to 1832°F (2.5% + 5) -40 to 40°C (4°C) 40°C to 500°C (1.0% + 4) 500°C to 1000°C (2.0% + 4)
-40°F to 1832°F
Temperature (°C)
-40°C to 1000°C
Overload Protection 600V rms CAT Rating CAT III 600V