Ancor Catalog 2024

44 WIRE MANAGEMENT

ancorproducts.com

Wire Seals • Made of Nylon 6/6 flame resistant, self extinguishing Buna-N form seal • All seals exceed NEMA Type 4X and Type 6 specs • Overlapping clamping spines allow for superior pull-out protection and resistance • Strain relief fittings are resistant to salt water, acids, alkalis, alcohol, oils and are non-corrosive for use in the marine environment • Good underwater to 300 feet / 91.4 m (150 PSIG) provided there is a liquid tight seal between body and housing • Provide low cost cable entries into panels and junction boxes • UL 94 v-0

765000

765010

Clearance Hole

Body Length

Thread Length

Qty/ Pkg Part #

Description For Use with Round Cable 18–10 AWG Round Cable 10-2 AWG

Thread Size Cable Range

764998 765000

3/8" NPT 1/2" NPT

.08"–.24" 2–6 mm

.68"

.87"

.59" .51"

1 1

.20"-.47"

5–12 mm .83"

1.06"

Round or Flat Cable

4–1, 14/3-12/3 & 12/2–10/2 AWG

765002

1/2" NPT

.24"-.55"

6–14 mm .83"

1.10"

.51"

1

765004 765006 765010 765012

Round Cable 1–3/0 AWG Round Cable 4/0 AWG

3/4" NPT

.51"-.71" .71"-.98" .31"-.56" .31"-.56"

13–18 mm 1.05" 18–25 mm 1.35" 8–14 mm .83" 8–14 mm 1.05"

1.22" 1.53" 1.10" 1.22"

.51" .75" .51" .51"

1 1 1 1

1" NPT

Flat Cable Flat Cable

14/3-12/3 & 10/2

1/2" NPT 3/4" NPT

12/3

Grommets • Provide instant abrasion resistance to wires passing through panel holes • Flexible black vinyl makes installation simple

Qty/ Pkg Part #

Hole Size

Inside Diameter Panel Width

760375 760500

3/8" 1/2"

10 mm 13 mm

1/4" 3/8"

6 mm

3/32" 3/32"

2 mm

5

10 mm

2 mm 5

1/4–3/4" Assortment Combo Pack (10 each of 1/4", 5/16", and 3/8", 5 each of 1/2", 11/16", and 3/4")

750000

45

TECH TIP

Spiral Wrap & Split Loom • Permits flexible routing of cable harnesses • Provides abrasion protection for wire and cable

Wire Bundling per ABYC Guidelines ABYC states: “Conductors that may be exposed to physical damage shall be protected by loom, conduit, tape, raceways, or other equivalent protection. When AC and DC conductors are run together, the AC conductors shall be sheathed, bundled, or otherwise kept separate from the DC conductors. Loom used to cover conductors shall be self-extinguishing. The base product (or resin) shall be classified as V-2 or better, in accordance with UL 94, Tests For Flammability Of Plastic Materials.”

• Allows lead outs at any point for greatest ease of installation • Split loom temperature range is -40°F to 275°F / -40°C to 135°C

Marine Grade ® Spiral Wrap

Bundle Range

Diameter

Ft/Pkg Part # Min Max

Self-extinguishing Split Loom Diameter Ft/Pkg Part # 3/8" 10 mm 10' 453382 100' 453386

452251 3/16" 452381 5/16" 8 mm 452385 452501 25/64" 10 mm 452505 4.8 mm

2" 5 cm

1/4" 6 mm 10'

10'

3" 7.6 cm 4" 10.2 cm 5" 12.7 cm 7" 17.8 cm

3/8" 10 mm

100'

10'

453502 453506 453752 453756 453901 453906

10'

1/2" 13 mm

1/2"

13 mm

100'

100'

452751 3/4"

10'

10'

3/4" 19 mm

19 mm

3/4"

19 mm

452755

100'

100'

452900 1"

5'

5'

1"

25 mm

25 mm

1"

25 mm

452905

100'

100'

Powered by