Ancor Catalog 2024

16 WIRE & CABLE

ancorproducts.com

Shore Power Cord Conductor colors: black, white, green (and red 100319 only) • High visibility yellow jacket is weather and sunlight resistant • Ultra flexible insulation is abrasion resistant for “hard service” applications • 600 volt rated for extra heavy-duty service • 16/3 is 300 volt cable • Temp rating: 140°F / 60°C

Spool Length Part #

Nominal O.D.

Wt. per 1000'

Spool Length Part #

Nominal O.D.

Wt. per 1000'

10/3 STOW 100'

6/3 STW per/ft** 6/4 STW per/ft**

153710 153725

100320F 31/32"

540 lbs 254.4 kg

21/32" 17 mm

284 lbs 129 kg

24.4 mm

250'

10/3 STW 250'

100319F 1-5/64" 27.4 mm 695 lbs 316 kg SPC103, 100320F and 100319F are not tinned wire **50 ft minimum

21/32" 17 mm

284 lbs 129 kg

SPC103

Coaxial Cable Premium Tinned Copper • Features signal loss ratios of up to 50% less than other coaxial cables • Tinned copper center conductor as well as tinned copper outer braid for corrosion resistance and easy soldering • 96% braid for best signal strength and least interference with UV inhibited white jacket for longest life Coaxial Cable & Assemblies

Coaxial Cable Assemblies Premium Tinned Copper • All assemblies come with Ancor adhesive lined heat shrink to seal out moisture, provide strain relief and fight corrosion • 96% tinned copper braid for optimum protection against signal loss • 100% tinned copper center conductor and braid • No solder or special tools required • Special low loss SAT NAV extensions

Spool Length Part # Nominal O.D.

Wt. per 1000'

Wire Type

RG58C/U RG59U RG8X RG213

RG 58CU 100'

Insulation Material

PVC*

PVC

PVC

PVC*

150510 150525

3/16" 4.8 mm

26 lbs 11.8 kg

Nominal O.D.

3/16" 4.8 mm

1/4" 6.4 mm

1/4" 6.4 mm

13/32" 10.3 mm

250'

RG 59U 250'

AWG

20

23

16

13

151025 151050

1/4" 6.4 mm

36 lbs 16.3 kg

Conductor Stranding

19/33 Solid** 19/29 7/21 96% 96% 96% 96%

500'

Braid Coverage Wt. per 1000'

RG 8X 100'

26 lbs 11.8 kg

36 lbs 16.3 kg

40 lbs 18.1 kg

110 lbs 50 kg

151510 151525 151550 151560 151710 151725 151750

250' 500'

Impedance (Ohms) Capacitance/Ft. Attenuation/100' @50MHz

50

75

50

50

1/4" 6.4 mm

40 lbs 18.1 kg

30.8 pF 20.5 pF 26.0 pF 30.8pF

1000'

3.3db 2.4db 2.5db 1.3db 4.9db 3.4db 3.7db 1.9db

RG 213 100'

@100MHz @1000MHz

21.5db 12.0db 13.5db 8.0db Velocity of Propagation 66% 66% 78% 66% * non-contaminating insulation ** copperweld

13/32" 10.3 mm

110 lbs 50 kg

250' 500'

TECH TIP

Ends Description

Wire Length Part #

189800 189849

RG58CU Two ends assembled 3' RG8X One end assembled 50'

Ancor Recommends • RG 58CU for interconnecting electronic equipment

• RG 59U for TVs and some SAT NAVs • RG 213 for VHF runs more than 50 feet • RG 8X for VHF runs less than 50 feet

Powered by