Whale Marine Catalogue

HIGH CAPACITY FRESHWATER KIT

DOUBLE STACK FRESHWATER PUMP SYSTEM

Twin pump design efficiently delivers smooth water flow in vessels with up to 8 outlets u Fast installation - pre-assembled system

u Reduces noise and vibration by preventing pump cycling u Small footprint - ideal for installation in tight spaces

u Unique mounting bracket ensures compact footprint and includes vibration reducing feet u Robust industrial grade external pressure switches are ignition protected and require no relays

Model

High Capacity Freshwater Kit

PART NUMBER

UF2415B

UF2425B

UF3615B

UF3625B

Accumulator

2 ltrs (0.53 US Gals)

tank size Weight

8.7kg (19lbs)

9.8kg (22lbs)

Voltage

12V d.c.

24V d.c.

12V d.c.

24V d.c.

Recommended fuse size per pump

10 amps

5 amps

12 amps

8 amps

Hose connection

19mm (¾”) barb

Cable size

2.5mm² (20AWG)

Materials

Pump Body: Glass-filled Polypropylene Aluminium and Powder-coated Steel Diaphragms: Santoprene ® , Valves and Feet: Monoprene ® , Seals: Nitrile ®

Materials in contact with fluid

Glass-filled Polypropylene, Monprene ® , Nitrile ® , Stainless Steel, Brass, Santoprene ®

Service kits

AK1314 - Low Pressure Switch, AK1315 - High Pressure Switch, AK2415 - 12L 12V Pump, AK2425 - 12L 24V Pump, AK3615 - 18L 12V Pump, AK3625 - 18L 24V Pump, PT0200 - Accumulator Tank

Model

Performance

PART NUMBER

UF2415B

UF2425B

UF3615B

UF3625B

Maximum suction lift

20m (66ft)

30m (99ft)

20m (66ft)

30m (99ft)

Maximum discharge head

3m (10ft)

Cut out pressure

Pump 1: 3 bar (45 psi) Pump 2: 2 bar (30 psi))

Cut in pressure

Pump 1: 2 bar (30 psi) Pump 2: 1.4 bar (20 psi)

Factory pre-charge pressure

2.2 bar (32 psi)

Open flow rate per minute No. of outlets

24 ltrs (6.3 US Gals)

32 ltrs (8.4 US Gals)

Up to 6

Up to 8

For further guidance on the selection of the correct pump, please see page 121

CA WARNING: Handling recreational marine vessel parts can expose you to chemicals such as phthalates and lead, which can cause cancer and reproductive harm. To minimize exposure, service the vessel outdoors or in a well-ventilated area, wear gloves, and wash your hands. For more information see www.P65Warnings.ca.gov/marine-vessel-parts.