HIGH CAPACITY FRESHWATER KIT
DOUBLE STACK FRESHWATER PUMP SYSTEM
Twin pump design efficiently delivers smooth water flow in vessels with up to 8 outlets u Fast installation - pre-assembled system
u Reduces noise and vibration by preventing pump cycling u Small footprint - ideal for installation in tight spaces
u Unique mounting bracket ensures compact footprint and includes vibration reducing feet u Robust industrial grade external pressure switches are ignition protected and require no relays
Model
High Capacity Freshwater Kit
PART NUMBER
UF2415B
UF2425B
UF3615B
UF3625B
Accumulator
2 ltrs (0.53 US Gals)
tank size Weight
8.7kg (19lbs)
9.8kg (22lbs)
Voltage
12V d.c.
24V d.c.
12V d.c.
24V d.c.
Recommended fuse size per pump
10 amps
5 amps
12 amps
8 amps
Hose connection
19mm (¾”) barb
Cable size
2.5mm² (20AWG)
Materials
Pump Body: Glass-filled Polypropylene Aluminium and Powder-coated Steel Diaphragms: Santoprene ® , Valves and Feet: Monoprene ® , Seals: Nitrile ®
Materials in contact with fluid
Glass-filled Polypropylene, Monprene ® , Nitrile ® , Stainless Steel, Brass, Santoprene ®
Service kits
AK1314 - Low Pressure Switch, AK1315 - High Pressure Switch, AK2415 - 12L 12V Pump, AK2425 - 12L 24V Pump, AK3615 - 18L 12V Pump, AK3625 - 18L 24V Pump, PT0200 - Accumulator Tank
Model
Performance
PART NUMBER
UF2415B
UF2425B
UF3615B
UF3625B
Maximum suction lift
20m (66ft)
30m (99ft)
20m (66ft)
30m (99ft)
Maximum discharge head
3m (10ft)
Cut out pressure
Pump 1: 3 bar (45 psi) Pump 2: 2 bar (30 psi))
Cut in pressure
Pump 1: 2 bar (30 psi) Pump 2: 1.4 bar (20 psi)
Factory pre-charge pressure
2.2 bar (32 psi)
Open flow rate per minute No. of outlets
24 ltrs (6.3 US Gals)
32 ltrs (8.4 US Gals)
Up to 6
Up to 8
For further guidance on the selection of the correct pump, please see page 121
CA WARNING: Handling recreational marine vessel parts can expose you to chemicals such as phthalates and lead, which can cause cancer and reproductive harm. To minimize exposure, service the vessel outdoors or in a well-ventilated area, wear gloves, and wash your hands. For more information see www.P65Warnings.ca.gov/marine-vessel-parts.
WHALEPUMPS.COM
50
Powered by FlippingBook