ACCUMULATOR PUMP KIT
SMOOTH CONSTANT FLOW IN ONE INTEGRATED KIT
Reduces water hammering and cycling u Combined pump and accumulator tank ensure a smooth even flow of water to all outlets
u Compact design installs easily in convenient locations u Reduced noise and vibration by preventing pump cycling u Easily plumbed into standard 1 / 2 ” or 3 / 8 ” pipework u Can be fitted to new or existing systems u Pump available separately
Model
Accumulator Kits
PART NUMBER
UF2214
UF2215
UF2224
UF2225
UF2015
UF8025
Accumulator tank size
2 ltrs (0.53 US Gals)
8 ltrs (2.1 US Gals)
Weight
3.9kg (8.5lbs)
5.4kg (11.9lbs)
5.9Kg (13lbs)
Voltage
12V d.c.
24V d.c.
12V d.c.
24V d.c.
Fuse size
10 amps
5 amps
8 amps
8 amps
Cable size
1.5mm² (16AWG)
Hose connection
Whale Quick Connect 15mm Female For (½”), Flexible Hose, Use WX1584 (supplied with kit), For ³⁄ 8 ” Flexible Hose, Use WU1215 and WU1280 (not supplied with kit)
Materials
Pump Body: Glass-filled Polypropylene Aluminium and Powder-coated Steel, Diaphragms: Santoprene ® , Valves and Feet: Monoprene ® , Seals: Nitrile, Tank: Butyl, Base: ABS, Fittings: Brass, Fasteners: Stainless Steel
Materials in contact
Glass-filled Polypropylene, Monprene ® , Nitrile, Stainless Steel, Brass, Santoprene ®
with fluid Service kits
AK1316 - Replacement Head, AK1317 - Microswitch Kit, AK1319 - Replacement Strainer (for freshwater), PT0200 - Accumulator Tank
Model
Performance
PART NUMBER
UF2214
UF2215
UF2224
UF2225
UF2015
UF8025
Maximum suction lift
3m (10ft)
Maximum discharge head
20m (66ft)
30m (99ft)
20m (66ft)
30m (99ft)
20m (66ft)
30m (99ft)
Maximum system pressure (Cut Out) Factory pre-charge pressure (+/-0.14 bar+/-2 psi) Open flow rate
2 bar (30 psi)
3 bar (45 psi)
2 bar (30 psi)
3 bar (45 psi)
3 bar (45 psi)
3 bar (45 psi)
1.5 bar (22 psi)
2.2 bar (32 psi)
1.5 bar (22 psi)
2.2 bar (32 psi)
1.4 bar (20 psi)
2.2 bar (32 psi)
12 ltrs
18 ltrs
12 ltrs (3 US Gals)
per minute
(3 US Gals)
(5 US Gals)
CA WARNING: Handling recreational marine vessel parts can expose you to chemicals such as phthalates and lead, which can cause cancer and reproductive harm. To minimize exposure, service the vessel outdoors or in a well-ventilated area, wear gloves, and wash your hands. For more information see www.P65Warnings.ca.gov/marine-vessel-parts. For further guidance on the selection of the correct pump, please see page 121
WHALEPUMPS.COM
48
Powered by FlippingBook